We are moving our operations. As a result, shipping times may be longer than normal. We apologize for any inconvenience.
Included: blower, thermostat, hot air plenum, combustion-state indicator light, automated combustion control, ash lip, ash lip, ash drawer, poker and scraper
▪ Intuitive start mode for fast and clean ignition
▪ Optimized combustion for low creosote formation
▪ Uninterrupted heat with on-demand boost based on thermostatic demand
▪ Among the lowest burn rates on the market (firewood savings)
▪ Up to 10 hours burn time
▪ 3.6 ft³ firebox
▪ 21" logs (loading over depth and width)
▪ EPA certified
▪ Proudly made in Canada
▪ Limited lifetime warranty
▪ Air filters help filter dirt before distributing hot air in your installation in addition to protecting the blower. The use of filters is strongly recommended.
▪ The fresh air return adapter can be added to the blower box to increase the efficiency of your system. This option allows you to take fresh air from the rooms and bring it to the furnace to be heated and redistributed in these same rooms. It allows more even air circulation to increase comfort.
Any installation must be done according to the data and drawings detailed in the owner’s manual.
Maximum input capacity (dry cordwood)(1) | 310,000 BTU | Overall dimension (Depth) | 51 1/8" |
Average electrical power consumption(2) | 330 W | Filter - Dimensions (Width x Height x Depth) | 15" x 20" x 1" (option) |
Optimum efficiency(3) | 83.2% | Door opening size (Height) | 10" |
Average particulate emission rate(4) (5) | 0.095 lb/mmBTU (0.041 g/MJ) | Door opening size (Width) | 13 3/4" |
Nominal heat output at 15lb/ft³ fuel loading density | 75,000 BTU | Distance-center of the flue outlet to floor | 37 1/8" |
Minimum overall heat output rate(4) (5) | 42,234 BTU/h (12.4 kW) | Distance-center of the flue outlet to side unit | 13 7/8" |
Minimum delivered heat output rate(6) | 13,297 BTU/h (3.9 kW) | High-efficiency certified appliance | Yes, EPA 2020 approved |
Maximum overall heat output rate(7) | 47,052 BTU/h (13.8 kW) | Steel thickness-body | 3/16" |
Minimum overall heat output rate(7) | 19,354 BTU/h (5.6 kW) | Steel thickness-top | 1/4" |
Maximum average delivered efficiency (LHV)(8) (9) | 65 % | Warranty | Limited lifetime |
Minimum average delivered efficiency (HHV)(8) (10) | 60.7 % | Maximum log length | 21" |
Maximum average overall efficiency (LHV)(11) (9) | 82 % | Canadian Standard (emissions) | CSA B415.1-10 |
Minimum average overall efficiency (HHV)(11) (10) | 76.6 % | USA Standard (emissions) | EPA |
Optimum heat transfer efficiency | 81 % | Canadian Standard (safety) | CAN/CSA B366.1 |
Recommended heating area(12) | 1,000 - 2,500 ft² | USA Standard (safety) | UL 391 |
Average CO(13) | 8.78 lb/mmBTU (3.78 g/MJ) | Hot air plenum - Height (minimum - maximum) | 22 3/8" x 26 7/8" |
Maximum burn time(12) | 10 h | Hot air plenum - Minimum height of the furnace with plenum | 63 1/2" min. for 69" ceiling | 73 1/4" to 88" for a ceiling of 78 1/4" to 93" and more |
Fuel type | Dry cordwood (16" recommended) | Shipping weight | 758 lb (344 kg) |
Overall firebox volume | 3.6 ft³ | Log positioning | Loading over width and over depth |
Size | Extra Large | Evacuation direction | Horizontal |
Firebox lined with refractory bricks | Yes | Glass surface - W x H | 12 3/8 x 10 1/8" |
Baffle type | C-Cast or equivalent | Stainless-steel secondary-air system | Yes |
Recommended chimney diameter | 6" | Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Flue outlet diameter | 6" | Type of chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
Firebox size (Height) | 16 1/8" | Door type | Single, glass with cast iron frame |
Firebox size (Width) | 18 3/4" | Premium quality blower included (CFM) | Included |
Firebox size (Depth) | 22 1/2" | Glass type | Ceramic glass |
Overall dimension (Height) | 63 1/2" min. | Blower (hp | speed | CFM) | 1/3 | 1 | 1,135 |
Overall dimension (Width) | 27 3/4" |
*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
**Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.
1. Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.
2. Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
3. Optimum overall efficiency at a specific burn rate (LHV).
4. Based on delivered heat output.
5. This appliance is officially tested and certified by an independent agency.
6. Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.
7. Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.
8. Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturerās estimation.
9. Lower Heating Value of the fuel.
10. Higher Heating Value of the fuel.
11. Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
12. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
13. Carbon Monoxyde. Based on overall heat output at 10 lb/ft³ fuel loading density.